Titanium V 12 V 3.5 A Backup Power Supply & Battery Charger
R485.00 Incl. VAT
The GSS Titanium V is a 12 V DC battery-backed power supply and charger for alarm, access-control and other compatible 12 V security equipment where continued operation during a mains failure is required.
- Rated at 3.5 A with 12/13.8 V DC operation for powering compatible equipment and charging a backup battery.
- Intelligent switch-mode battery charging with built-in battery protection.
- Overload, overvoltage and short-circuit protection with automatic recovery after applicable faults.
- Selectable audible mains-failure warning plus an AC-fail signal output for system monitoring.
- Indoor installation only; wiring, mounting and servicing should be carried out by a suitably qualified person.
Description
Titanium V GS12035DC-UPS-PL 12 V backup power for security systems
The Titanium V GS12035DC-UPS-PL combines a 12 V DC power supply, battery charger and battery-backup control in one compact powerpack. It is designed for compatible alarm, access-control and other 12 V security equipment that needs to remain powered when mains electricity fails.
Its 3.5 A rating, intelligent switch-mode charging and built-in protection make it a practical choice for professionally installed security systems where both reliable DC power and automatic battery backup are required.
Is This Right for You?
The Titanium V is suited to 12 V security installations where the total connected load remains within the unit’s rated capacity. The manufacturer’s wiring information specifically illustrates use with an alarm control panel and radio equipment.
It is particularly useful where you want the power supply to charge a backup battery during normal operation and automatically support the connected equipment during a mains failure.
How It Works
During normal mains operation, the Titanium V supplies the connected 12 V equipment while managing the backup battery through its intelligent switch-mode charging circuit. If mains power fails, the battery-backup system allows the connected load to continue operating from the battery.
A selectable audible warning can indicate mains failure, while the dedicated AC-fail output provides a positive signal during an AC failure and returns to 0 V when mains power is restored. This allows compatible alarm or monitoring equipment to detect a power-loss condition.
Why Choose This Product?
- Integrated battery charging: the PIC-controlled switch-mode charging system manages the backup battery without requiring a separate charger.
- Useful fault protection: overload, overvoltage and short-circuit protection help protect the power supply and connected equipment.
- Automatic recovery: overload and short-circuit protection are designed to recover after the fault condition is removed.
- Mains-failure monitoring: an audible warning and AC-fail output make loss of mains power easier to detect or integrate into a security system.
- Battery protection: built-in protection includes a warning before battery cut-off when the battery becomes too low.
Before You Buy
- Use only with compatible 12 V DC equipment and ensure the combined system load is appropriate for the 3.5 A rating.
- A suitable 12 V backup battery is required to provide battery-backed operation.
- Backup operating time depends on the connected load, battery capacity, battery condition and installation.
- The unit is intended for indoor installation and is not protected against water.
- Install the unit where sufficient ventilation is available to dissipate heat.
- Mains power must be disconnected before wiring connected equipment to the unit.
- Mounting, maintenance and repair should be carried out by a suitably skilled and authorised person.
- The manufacturer’s one-year warranty is subject to correct installation procedures and installation by a qualified person.
Technical Specifications
| Manufacturer | GSS Energy Storage |
|---|---|
| Series | Titanium V |
| Model / SKU | GS12035DC-UPS-PL |
| Product type | DC UPS / battery backup power supply and charger |
| Rated current | 3.5 A |
| DC rating | 12/13.8 V DC |
| Battery charger | Intelligent switch-mode charging controlled by PIC processor |
| Overload protection | 115%–135% of rated power; pulsing hiccup shutdown with automatic recovery |
| Overvoltage protection | Yes |
| Short-circuit protection | Yes, with recovery |
| Battery protection | Built in |
| Mains-failure warning | Audible tone; link-selectable enable or disable |
| Power-failure buzzer | Sounds every 30 seconds when enabled |
| Low-battery warning | 30-second warning before battery cut-off |
| AC-fail signal output | Positive during AC failure; returns to 0 V when AC is restored |
| Installation environment | Indoor only |
| Standards stated in manufacturer instructions | EN55022, EN61000-3-2/-3, EN55024, SANS IEC 62368-1 |
| Warranty | 1 year, subject to correct installation procedures and installation by a qualified person |
What’s in the Box
- 1 × Titanium V GS12035DC-UPS-PL DC UPS battery backup power supply
7Ah – 8Ah 12V Battery sold separately
Additional information
| Weight | 895 g |
|---|---|
| Dimensions | 200 × 180 × 87 mm |